Filter Results By:

Products

Applications

Manufacturers

Showing results: 1276 - 1290 of 2630 items found.

  • DC Power Module, 8V, 12.5A, 100W

    N6742B - Keysight Technologies

    The Keysight N6742B is a 100 W basic DC power module that provides programmable voltage and current, measurement and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources such as fixture control.

  • DC Power Module, 150V, 2A, 300W

    N6777A - Keysight Technologies

    The Keysight N6777A is a 300 W basic DC power module that provides programmable voltage and current, measurement and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources such as fixture control.

  • DC Power Module, 20V, 5A, 100W

    N6743B - Keysight Technologies

    The Keysight N6743B is a 100 W basic DC power module that provides programmable voltage and current, measurement and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources such as fixture control.

  • DC Power Module, 60V, 5A, 300W

    N6775A - Keysight Technologies

    The Keysight N6775A is a 300 W basic DC power module that provides programmable voltage and current, measurement and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources such as fixture control.

  • DC Power Module, 35V, 3A, 105W

    N6744B - Keysight Technologies

    The Keysight N6744B is a 105 W basic DC power module that provides programmable voltage and current, measurement and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources such as fixture control.

  • DC Power Module, 20V, 15A, 300W

    N6773A - Keysight Technologies

    The Keysight N6773A is a 300 W basic DC power module that provides programmable voltage and current, measurement and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources such as fixture control.

  • DC Power Module, 5V, 20A, 100W

    N6741B - Keysight Technologies

    The Keysight N6741B is a 100 W basic DC power module that provides programmable voltage and current, measurement and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources such as fixture control.

  • Digital (1kV below) Insulation Tester

    2151 IN - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● 68 × 34mm(2.677” × 1.338”) large LCD display.● 3½ digital LCD(2000 counts) a LCD indicated instrument for insulation.(MΩ), continuity(Ω) and AC voltage.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA DC load.● >200mA short circuit testing current for a resistance tests.● Auto ranging.● REL function.● Auto power OFF.● Fuse protection.● Auto data hold.● BS 16 edition.

  • Battery Voltage Recorder

    BVR Series - IBEKO Power AB

    Battery voltage recorders from BVR series are designed to serve as a support tool for cell voltage measurement during battery capacity testing.During capacity testing, cell voltage, temperature, inter-cell connection voltage, and specific gravity should be measured in order to determine failling cells in the string that should be replaced.Furthermore, IEEE standards for stationary batteries applications stipulate periodical measurement of overall string voltage, as well as cell voltage and temperature.The BVR Series is the perfect tool for that purpose. All measurements are automatically saved in device’s internal memory. Additionally, DV-B Win software helps the user to download all measured results. Furthermore, the user can create test reports and export them to various formats.BVR series includes two models: BVR11 and BVR22. These are rechargeable handheld devices intended for performing monthly battery inspections and support tools during capacity testing. The list of the applications of these instruments includes:Efficient supplement to BLU series of battery load units during battery discharge testingMonthly inspections of large battery banksAmbient temperature measurementCurrent measurement using current clampsUSB and Bluetooth communication with PCSimultaneous string voltage and current measurement to analyze a discharge test processThe BVR22 model provides Bluetooth communication with an external density meter, for transferring electrolyte specific gravity and temperature readings.

  • Milliohm Meters

    Chroma 16502 - Chroma Systems Solutions, Inc.

    With a basic accuracy of 0.05%, Chroma 16502 offers a 0.001mΩ ~1.9999MΩ wide measurement range. It provides measurement range with 4 1/2 digits resolution. The fast measurement time is 65 ms. It suits component evaluation on production line. Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurement. DC test current output mode is used to fasten measurement speed for inductive DUT. Dry-circuit test current output mode is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 20mV.

  • Lightning Surge Generator

    SKS-0510I - Shanghai Sanki Electronic Industries Co., Ltd.

    The lightning surge generator SKS-0510I fully complies with the new standards of IEC61000-4-5, EN61000-4-5 and GB/T17626.5; it provides pulse test voltages up to 10kV, which can meet the severity levels of various product standards; Covers the two surge waveforms specified in the standard 1.2/50ms (short-circuit current is 8/20μs) and 10/700ms (short-circuit current is 5/320μs), and a variety of internal resistances are built-in for customer use; Two kinds of surge waveforms, and built-in a variety of internal resistances for customers to use; AC and DC samples can be tested, the rated current can reach 32A.

  • Digital Power Meter, 30A

    66205 - Chroma Systems Solutions, Inc.

    Voltage Ranges:15/30/60/150/300/600 Vrms1200Vrms (optional)Current Ranges : 0.005/0.02/0.05/0.2/0.3/0.5/2/5/20/30 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bitsAnalog/Digital converters withmax samipling rate up to 250kHzCapable of meeting the IEC 61000-4-7harmonics measurement requirementsSmart Range function provides seamlesspower integration measurement underauto range modeSupports external shunt and CT forhigher current applications5 mA minimum current range &0.1mW power resolutionMeets ENERGY STAR /EN 50564/IEC 62301/ErP requirementsUser-define criteria providesautomatic PASS/FAIL indicationsTHD and user-specify order distortionmeasurementInrush current and energy measurementsVoltage/ Current harmonics measurementsup to 100 ordersUSB (Host) interface provides data loggingfunctionalitySupport GPIB, USB, RS232, LAN (option)interface

  • Natural Cooling Input 380VAC 3 Phase to Output 190-300VDC 10A-40A Rectifier Battery Charger

    SD230D20ZZ - Zhejiang Sandi Electric Co., Ltd

    SANDI “SD” series intelligent high-frequency switch power supply modules are specially developed to meet the demands of modern DC system. The charger rectifiers are designed with world leading patent technology “resonant voltage type soft switching power supply technology”. They feature high efficiency and stability, intelligent control, small size and light weight. Standard RS-485 interface, easy to connect with automation system. “Four remotes” functions, intelligent management. The products are widely used in power plant, substations and etc..Main characteristic of the moduleModularization design, realize N+1 backup;The friendly man-machine interface. Large screen to show, realize man-machine dialogue operate really.RS-485 inrerface, realize “4 remote” function with monitor machine.High efficiency, Nearly 95%-96%;Lightly, 230V/10A natural cooling module only 9kg;Little volume, 230V/10A natural cooling module dimension only 325mm×230mm×130mm;After the full bridge rectifying circuit rectifies 3-phase AC to DC, then adjusted by reactive PFC, power factor>0.94;Function against reverse pour: each module has been added diode against reverse pour at output terminal.LED digital screen, digital calibrate, stable current ,fault alarm Main characteristic of the ModulesThe friendly man-machine interface. LED digital screen, digital calibrate, stable current ,fault alarmHigh efficiency, up to 95%-96%;Light weight, Small sizeAfter the full bridge rectifying circuit rectifies 3-phase AC to DC, then adjusted by reactive PFC, power factor>0.94;Unequal current ratio of parallel connection<+/-3%, can ensure twenty modules work well by parallel connection.Multiple protections including over/under voltage, current limiting, short-circuit, parallel protection, over-temperature protection.Output over-voltage protectionTo prevent the disastrous accident caused by output overvoltage, there is overvoltage protection circuit in the module. Once the output voltage is higher than the threshold, the module locks up automatically and fault indication light is on, the faulty module quits work automatically and doesn’t affect the normal operation of the entire system.Output current limiting protectThe output current cannot increase infinitely. The maximum value of the output current of each module is limited to the rated output current 105%, in this range, the output current value of the module is continuously adjustable. If the load output of the module, the module will play down the output voltage.Output short-circuit protectionWhen short circuit, the output voltage drops to 0 immediately. Limit the short circuit current under 15% of rated output current. The module will not be damaged under short circuit state for a time, and resumes to work automatically after debugging. Module parallel protectionThere is parallel protection circuit in each module to ensure that when the fault module quits the system, the normal work of other modules and the system won’t be effect.Output over-current protectionThe output current cannot increase infinitely. If overloaded, the output voltage decreases automatically to protect the power components. The over current protection can be resumed automatically.

  • Wide-range High-power DC Power Supply

    IT6500 Series - I-TECH Electronic Co., Ltd

    With ITECH’s latest technology, the IT6500 series offers a full-featured high-performance power test solution. With fast response these DC power supplies provide users with a new level of power supply performance. From 800W to 30 kW, the whole series include more than 100 models. The maximum output voltage and current is up to 1000V and 1200A respectively. With its autoranging capabillity, it also has a super wide range of voltage and current applications. Users can choose the power supply that fits their testing requirements perfectly. In combination with the IT-E501 power dissipater unit, the current sinking capacity of IT6500C can be 100%, 200%, 300% and the power sinking up to 300% of the Sourcing capability. As a high-speed two-quadrant power supply, IT6500C (1800W-30kW) series has a priority function so as to realize high-speed current transition between power supply mode and electronic load mode, to achieve fast switching between sourcing and sinking current, even can achieve seamless switching under certain conditions. IT6512, IT6513 and IT6500C series power supplies provide built-in DIN40839 and ISO-16750-2 testing curves, support solar panel I-V curve simulation function.

  • High Voltage Tracking Resistance (HVTR)

    UL 746A - National Technical Systems

    The High Voltage Tracking Resistance (HVTR) test method is used to assess the susceptibility to tracking of insulating materials that are exposed to high voltages outdoors. Insulators installed in the open are often at the mercy of humidity. Their electrical insulation properties can deteriorate to such an extent as a result that tracking paths are formed on the insulator surface. This test determines the tracking resistance that defines the dielectric strength of the insulating material surface and the maximum allowable leakage current (tracking).

Get Help